-
Testing of breakdown voltage of transformer oil - Sample condition
Testing of breakdown voltage of transformer oil - Sample conditionIEC 156 oil dielectric testerThe test is carried out, unless otherwise specified, on the sample as received without drying or degassing. At the time of test, the temperatures of the test liquid and ambient air shall not differ by more ...
-
Testing of breakdown voltage of transformer oil - Sampling
Testing of breakdown voltage of transformer oil - SamplingIEC 156 oil dielectric test set7.1 Sample containersSample size should be approximately three times the capacity of the test cell. Appropriate sample containers shall comply with IEC 475. An amber glass bottle is the preferred container. Clear ...
-
Testing of breakdown voltage of transformer oil - test assembly preparation
Testing of breakdown voltage of transformer oil - test assembly preparationIEC 156 automatic BDV test kitIt is recommended that a separate test cell assembly be reserved for each insulating liquid type. Test assemblies shall be stored in a dry place, covered and filled with dry insulating liquid of the ...
-
Testing of breakdown voltage of transformer oil - electrode preparation
Testing of breakdown voltage of transformer oil - electrode preparationIEC 156 BDV test kitNew electrodes, pitted electrodes, electrodes which have not been properly stored for a considerable time shall be cleaned by the following procedure:(1) Clean all surfaces with a suitable volatile solvent and ...
-
Test assembly of testing of breakdown voltage of insulating oils
Test assembly of testing of breakdown voltage of insulating oilsIEC 156 semi-automatic oil test set4.1 Test cellThe volume of the cell shall be between 350ml and 600ml. The cell shall be made of material that is electrically insulating, transparent and chemically inert, resistant to the insulating liquid ...
-
Electrical apparatus of testing of breakdown voltage of insulating oils
Electrical apparatus of testing of breakdown voltage of insulating oilsIEC 156 automatic oil test setThe electrical apparatus consists of the following units:(a) Voltage regulator(b) Step-up transformer(c) Switching system(d) Energy limiting devicesTwo or more of these units may be integrated in any ...
-
Normative references of testing of breakdown voltage of insulating oils
Normative references of testing of breakdown voltage of insulating oilsIEC 156 oil test setNormative referencesThe following normative documents contain provisions which, through reference in this text, constitute provisions of this International Standard. At the time of publication, the editions indicated ...
-
Scope of testing of breakdown voltage of insulating oils
Scope of testing of breakdown voltage of insulating oilsIEC 156 insulating oil dielectric breakdown testingScopeThis International Standard specifies the method for determining the dielectric breakdown voltage of insulating liquids at power frequency. The test portion, contained in a specified apparatus, ...
-
Introduction to testing of breakdown voltage of insulating oils
Introduction to testing of breakdown voltage of insulating oils IEC 156 MG-II oil dielectric strength test setAs normally applied, breakdown voltage of Insulating liquids is not a basic material property but an empirical test procedure intended to indicate the presence of contaminants such as water and ...
-
What is IEC?
What is IEC?IEC 156 MG-II oil dielectric test set - Insulating liquids - Determination of the breakdown voltage at power frequency(1) IEC is short for International Electrotechnical Commission. The IEC (International Electrotechnical Commission) is a worldwide organization for standardization comprising ...