Libya tender for the flash point for oil transformer
General Electrical Company of Libia (GECOL)
Tender Main Committee
Technical specifications for the flash point for oil transformer
1. Power supply: AC(220 +/-10%)V, 50Hz

2. Temperature measurement
Range: Room temperature - 300 degree
Repeatability: not more than 2 degree
Reproducibility: not more than 4 degree
Accuracy: 0.1 degree

3. Heating rate
Procedure A: 5 - 6 degree/min
Procedure B: 1 - 1.6 degree/min
Automatic control and manually adjustable.

4. Stirring rate
Procedure A: (90 - 120)RPM
Procedure B: (250+/-10)RPM
Automatic control and manually adjustable.

5. Igniting mode
Igniting source: gas (or other civilian fuels, the same below)
Electric ignition. Gas flame
diameter: 3.2mm - 4.8mm

6. Ambient temperature: less than 40 degree

7. Relative humidity: less than 80%

8. Maximum power consumption: 350W