ASTM D6668 Standard Test Method for Discrimination Between Flammability Ratings of F = 0 and F = 1
10. Report
10.1 Report whether or not burning as defined in 3.1.1 occurs at the test temperature.
10.2 If no burning occurs, report that the Flammability Hazard Rating of the sample is zero (F=0) provided that no conflicting properties of the sample require a higher rating.
10.3 If burning occurs, report that the Flammability Hazard Rating of the sample is one (F=1) provided that no conflicting properties of the sample require a higher rating.
11. Precision and Bias
11.1 No information is presented about either precision or bias of Test Method D6668 for measuring flammability ratings since the test result is nonquantitative.
12. Keywords
12.1 burning; flammability hazards; flammability rating