12. Report
12.1 In reporting density, give the test temperature and the units (for example, density, 20°C = x.xxxxx g/mL). In reporting relative density (specific gravity), give both the test temperature and the reference temperature, but no units (for example, relative density (specific gravity), 20/4°C = x.xxxxx). Carry all calculations to one digit beyond the last significant figure, but report the final result to the fifth decimal place (0.00001).

13. Precision and Bias
13.1 Precision - Results, using the 25-mL Bingham-type pycnometer, should not differ from the mean by more than the following amounts:


NOTE 7 - The precision for this method was not obtained in accordance with RR:D02-1007.

13.2 Bias - The difference of results from the established values when compared to pure reference materials is not expected to be more than more or less 0.00003 g/mL. Specific bias has not been established by cooperative testing.

14. Keywords
14.1 Density; pycnometer; relative density; specific gravity